5ml
Lithium Heparin Whole Blood
Sodium Heparin Whole Blood
EDTA Trace Metal tube (Navy Blue
Tube) Whole Blood EDTA
No gel separator tubes
17 days
Refrigerated
Normal Range Less than 0.5ug/L
Chromium: 1 ug/L = 1 ppb (parts per billion)
Recommended range for general population: less than 0.5 ug/L
Toxicity: greater than or equal to 17 ug/L
UK MHRA recommendations for metal-on-metal hip replacements:
RANGES APPLY TO WHOLE BLOOD SAMPLES
If either cobalt or chromium ion levels are elevated above 7 ppb (i.e. 134 nmol/L Cr or 119 nmol/L Co) then a 2nd
test should be performed three months after the first in order to identify patients who require closer surveillance,
which may include cross-sectional imaging.
Expected chromium and cobalt concentrations with well functioning hips:
Metal on plastic: chromium 0.8 ug/L; cobalt 0.6 ug/L
Unilateral metal/metal: chromium 2.3 ug/L; cobalt 1.8 ug/L
Bilateral metal on metal: chromium 2.3 ug/L; cobalt 2.6 ug/L
SAMPLE REQUIREMENTS FOR COAGULATION TESTS
PROCEDURE
Sample Requirements and Collection
Transportation and Storage